...
Image Save Options Page Anchor imagesaveoptions imagesaveoptions
This dialog is used to set the various image save options that are available.
The "Save Options" selection allows the user to select the type of data to be written to files. Raw Data is the unprocessed data coming from the sensor, which will be in the format the sensor is outputting, for example Bayer or YCbCr data. The Processed Data is RGB output data which has been converted from Bayer or YCbCr by DevWare. The image will also include any of the image processing pipeline that has been enabled. The Processed Data can be saved in either a 24bpp Bitmap file or 48bpp TIFF file. By default the register information is saved in the accompanying .TXT file.
Also available are the options on where to save the images. Note; if both "Auto File Name Increment and Save" and "Hold Still Image in Main Window" are disabled, the "Grab" and "Snapshot" will not be able to actual provide images to save.
After a Still Image is captured, the "Filmstrip" dialog appears if the "Hold Still Image in Main Window" option is selected. This dialog shows thumbnails of the captured image(s). The user can then right-click on the image for various options, including opening the image for view, saving the image, and selecting the type of image.
"Save Mouse Selection Rectangle Only"; only the saved image will show the rectangle-only - the filmstrip will show the full image.
Note: Overlays (Watch and/or Embedded Data) will not appear on a .raw image. Instead, they will appear on RGB-type image formats.
Reg Capture Page
This advanced feature allows the user to record the state of specific registers when performing a still image capture. A single register or a range or registers can be selected at once and added to the list. Multiple entries can be added to the list and each can be grouped into custom named categories.
Normally, when the Capture button on the Toolbar(See 2.2.2) is pushed and the "TXT (registers)" option is checked on the Save Options page a "capture####_info.txt" file is created. This file contains a variety of information, among which is the entire sensor register state at the time of the capture. For some purposes this may be more information than is necessary. The Reg Capture page allows the user to record only the register states they are interested in during the capture and simplifies subsequent locating or viewing within the .txt file.
Reg Capture appends any user defined categories to the end of the .txt file. To ease viewing and reduce the filesize, the user can remove the full register state dump. Expand the General category in the list box and uncheck the "All Registers" entry. By default this option is enabled (checked).
...