Introduction
This is the tool for customer to calculate proper register settings for Aptina ON Semiconductor image sensors/SOCsSOC/ISPs. The User only needs to specify input clock frequency (EXTCLK), desired output clock frequency (PIXCLK), and frame rate requirements. The Register Wizard will calculate and generate a list of register settings for users.
As shown in Figure 1, the sensor clock will be calculated based on frame rate requirements. Based on sensor clock frequency and required pixel clock, the SOC clock frequency is calculated. The SOC clock frequency should be as low as possible to provide the lowest power consumption, but still maintain continuous data flow from sensor to the output interface. A Rx/Tx FIFO with programmable watermarks allows for the continuous flow of data.
Supported Sensors
This new version of Register Wizard support newer Aptina Sensor/SOCs:
- AP0100CS, AP0101AT, AP0101CS
- AP0201AT, AP0202AT
- AR0130
- AR0132
- AR0133
- AR0134
- AR0135AT
- AR0136
- AR0140AT, AR0140CS
- AR0141CS
- AR0230AT, AR0230CS
- AR0260
- AR0261
- AR0262CP
- AR0330 (A-3135)
- AR0331 (A-3110)
- AR0333CS
- AR0551
- AR0832 (A-8141)
- AR0832E (A-8145)
- AR0833 (A-8741)
- AR0835/AR0835HS
- AR0841
- AR0842CP
- AR0880AI
- AR1230
- AR1231CP
- AR1330
- AR1331CP
- AR1335
- AR1335PD
- AR1336CP
- AR1820
- AR2020
- AR2520HS, AR2520US
- ARX550 (A-0375)
- AS0260 (A-2340SOC)
Excerpt | ||
---|---|---|
| ||
a tool for customer to calculate proper register settings for newer Aptina newer ON Semiconductor image sensors/SOCs/ISPs. |
Graphical User Interface
Figure 1. Regsiter Wizard PLL calculation Dock Window.
Figure 2 Register Wizard Timing calculation Dock Window.
Figure 3. Register Wizard calculated Register List Dock Window.
Operation Procedures
(1). Double-Click the RegisterWizard.exe located in the directory. As shown in Figure 4.
Figure 4. RegisterWizard.exe file location.
(2). Select a proper sensor configuration file from the Combo-Box in the Start-up panel as shown in Figure 5. If the Combo-Box does not show any files, please go to step (3) to open sensor configuration file.
Figure 5. Sensor Configuration File Combo-Box in the Register Wizard.
(3). User can Click menu "File"->"Open Config..." to open specific sensor configuration file other than the default files in the Combo-Box.
Figure 6. Open Sensor Configuration files in other locations.
(4). Select/Open the Sensor Configuration file in the File Dialog as shown in Figure 7.
Figure 7. Sensor Configuration File Dialog.
(5). Adjust windows/dock-windows settings, then click menu "Windows"->"Save State" to save current geometry settings.
Figure 8. Save Main Window and all the Dock Windows state/geometry.
(5). Select one of the "Image configurations" from the drop-down Combo-Box.
Figure 9. Image Timing Configurations/Use Cases for the Sensor.
(6). Click "Show Registers" to display the calculated output Register address/values.
Figure 10. Register List Dock Window in the Regsietr Wizard.
(7). Click "Advanced Parameters" to set up the sensor as shown in Figure 11 and Figure 12.
Figure 11. Advanced Image Timing Parameters.
Figure 12. Advanced PLL Parameters.
(8). Click "File"->"Save Config…" to save the current sensor configuration to a CFG file.
Figure 13. Save Configuration option in the Register Wizard.
(8). Click "File"->"Save INI" to save the current register settings to a INI file.
Figure 14. Save calculated register value to the INI file.