Note:The new application name for DevWare is "DevWareX".


DevWareX is a multi-platform implementation of DevWare, created with a more flexible GUI-generation tool. It has the same layout and controls as DevWare, but with additional features.
Here's a link to a description of DevWareX , and its new features.

The documentation in on this page still applies to DevWareX.

Anchor
Bookmark0
Bookmark0
Anchor
_Toc372623579
_Toc372623579
1. Welcome to

...

DevWareX

Image RemovedImage Added
Application setup:
           Installation(See 2.1.1)
           Running the Application(See 2.1.2)
Application layout and options:
           Menu Commands(See 2.2.1)
           Toolbar Buttons(See 2.2.2)
           Display Screen (See 2.2.3)
Main Dialogs:
           Info Dialog (See 2.2.5)
           Sensor Control Pages(See 2.2.4)
           Presets Dialog (See 2.2.6)
           Register Dialog(See 2.2.7)
           Register Log Dialog(See 2.2.8)
           Analysis Graph Dialog(See 2.2.9)
           Magnifier(See 2.2.10)
           Peek & Poke(See 2.2.12)
           Watch Dialog (See 2.2.13)
           Embedded Data Viewer(See 2.2.14)
           Options Dialog (See 2.2.15)
Troubleshooting:
           Warning Messages(See 2.2.16)
           Troubleshooting(See 2.2.17)
           Reporting a Bug(See 2.2.18) (mail to: Aptina-IMAGING_DEMO_BUGS@onsemi.com)

Anchor
Bookmark1
Bookmark1
Anchor
_Toc372623580
_Toc372623580
2.

...

DevWareX Help

Anchor
Bookmark2
Bookmark2
Anchor
_Toc372623581
_Toc372623581
2.1 Using the Application

...

The program can now be opened by going to the start menu and selecting "Programs" then "Aptina Imaging" then "DevWareDevWareX". A popup window will appear while DevWare DevWareX probes for attached devices. Then the main DevWare DevWareX window and a dialog box will appear that is slightly different for each sensor. Select the appropriate settings and click finish. Unless an error occurs(See 2.2.17) the application will open the display dialog and start capturing and displaying sensor images.
Note: Sensor data files can be manually loaded. Click the esc key to exit automatic probe. Make sure that the box next to "Automatically probe at startup" is unchecked. Click on "Sensor..." to browse for the corresponding sensor data (sdat) file. The file will be found in C:\Aptina Imaging\sensor_data.

...

DevSuite is ready to use on the Vista and Windows 7 operating systems when installed in the correct folder, but there is a requirement that the Demo2X demo board have a FW version of 28 or newer to match to the USB driver.
Note; the Demo3 FW is already Windows 7 compatible.
Firmware Upgrade
Note that a demo board with FW older than version 28 can only be upgraded on an XP operating system since only the XP-based USB driver supports the older versions of the FW. As of May of 2010, all newly delivered Demo2X boards will have version 28 of the FW. Demo2X boards received earlier than that may have an older FW version, and the FW version should be verified on an XP-based system before proceeding.
If you aren't sure that your FW has version 28 or newer, install the DevSuite SW on an XP-based system by following the instructions thru the section titled "Starting Up the Software" as found in "DevSuite Quick-Start Guide", which can be accessed from the DevWare DevWareX menu item "Documents". Then follow the FW upgrade instructions as found in "Demo FW User Guide", which can be accessed from the DevWare DevWareX menu item "Documents -> User Guides".
If you are fairly sure that your FW has version 28 or newer, then install the DevSuite SW on your Vista or Windows 7-based system by follow the instructions thru "Starting Up the Software" section of the Quick-Start guide. Once the USB cable is connected to the Demo2X demo board, Vista and Windows 7 will automatically attempt to download the matching USB driver from the Microsoft driver web site; if the driver installs correctly then your FW is current and no further action is required - continue with the instructions found in the Quick-Start guide.
If the USB driver download fails, it is either due to downgraded FW or a network problem. You can attempt to load the USB driver manually by following the instructions in the "Aptina Drivers User Guide", which can be accessed from the DevWare DevWareX menu item "Documents -> User Guides".
If the USB driver installs correctly then your FW is current and no further action is required - continue with the instructions found in the Quick-Start guide.
If the USB driver manual load failed, you will need to use an XP-based operating system to upgrade your Demo2X demo board as described earlier in this document. 
Software Installation
Do not install DevSuite in "C:\Program Files", due to the strict system security checking performed by Vista and Windows7.
The installer defaults to the recommended installation location of "C:\Aptina Imaging". If necessary this can be changed when prompted for the installation location.

Anchor
Bookmark61
Bookmark61
2.1.4 Windows 8: Additional Information

Aptina is in the process of getting our onsemi will not be getting the USB drivers certified to run on Windows 8. In the mean time, please follow the instructions in Windows8 USB3 Driver Usage instructions to be able to install and enable the drivers.

...

Command line parameters can be used with DevWareDevWareX.
Usage
Open a "CMD" window, navigate to the installation folder of C:\Aptina Imaging, and provide any of the following parameters.Note that parameters can be in all upper-case or all lower-case, and can be provided in any order.


devwarex [/help | ?] [/ini=["]filename["]]  [/preset=["]name["]]  [/camera=decimal number]  [/probe=0 | 1]  [/fullauto[=0 | 1]]  [/mono[=0 | 1]][/play[=0 | 1]]  [<sensor_sdat_file>.xsdat] [/nul]

  • /help or ? - Display this page.  You are given the option to continue to DevWareX or to exit.  Note: if "?" is used, all other parameters are ignored.
  • /ini=filename or /ini="filename" - Specify the INI file to be used, overriding the one selected by DevWare DevWareX if "Probe" is enabled.
  • /preset[=name] or /preset[="name"] - Run the optionally supplied specified preset. Note that the Startup Wizard dialog will be skipped whether or not the preset name is supplied.
  • /checksensor[=0 | 1 (default if not supplied)] - Disable | Force reading of sensor registers at startup. Disabled gives faster startup.
  • /camera=<number in decimal> - Force a specific camera id selection, in case more than one camera was detected.
  • /probe[=0 | 1 (default if not supplied)] - Disable | Force a "Probe". Note: ignored if SDAT filename is provided, and no "Probe" is performed if the parameter itself is not supplied.
  • /fullauto[=0 | 1 (default if not supplied)] - Disable | Force "Full Auto" option on the Startup Wizard. Note: enabled if parameter itself is not supplied.
  • /mono[=0 | 1 (default if not supplied)] - Disable | Force "Monochrome" option on the Startup Wizard. Note: disabled if parameter itself is not supplied.
  • /play[=0 | 1 (default if not supplied)] - Disable | Force "Play on Start" option on the Startup Wizard. Note: enabled if parameter itself is not supplied.
  • <sensor_sdat_file>.sdat - Specify the SDAT file to be used, overriding the one selected by DevWare DevWareX if "Probe" is enabled.
  • /nul - start without HW needing to be attached. An SDAT file can be loaded, and Presets can be run as long as it doesn't expect register reads to provide valid data.
  • /detfar - detect FAR sensor on start.
  • /warnings=filename - Specify the warnings file name.
  • /restorepresets - 1 to restore the additional Presets windows from the last session, 0 to not restore the windows.
  • /suppressallwindows - Start DevWareX will all windows suppressed - only the image display is enabled.
  • /startfullscreen - Start DevWareX in full screen mode.
  • /dll=DLLname. Include a new Transport DLL. And alternative is to copy the DLL to the Plugins folder.
  • <sensor_sdat_file>.xsdat - if opening an .xsdat file with no directory path given and the file doesn't exist, the sensor_data directory will be searched.

Anchor
Bookmark7
Bookmark7
Anchor
_Toc372623586
_Toc372623586
2.2 Application Layout and Options

...

Anchor
Bookmark9
Bookmark9
2.2.1.1 About Plug-ins

Introduction
The DevWare DevWareX application framework includes the ability to extend and customize its behavior.  Two types of extensions are supported:

  1. Dialog Plug-in - a dynamically linked library (DLL) which can be integrated with DevWare DevWareX and can be used to:
    • Display custom user interfaces.
    • Access and run DevWare DevWareX INI presets.
    • Access sensor registers.
    • Process the image data.

...

  1. Midlib Transport DLL - a DLL which can be integrated with the midlib library in order to create a "driver" for midlib/DevWare DevWareX in order to support new devices.  With a midlib Transport DLL you can:
    • Support an ON Semiconductor sensor on a device other than the Demo System camera so DevWare DevWareX or any other midlib-based application will work with the device.
    • Create a software simulated camera and sensor, simulating either an existing sensor or new sensor, and be able to use DevWare DevWareX as the user interface for the simulation.

...

The toolbar is displayed across the top of the application window, below the menu bar. The toolbar provides quick access to many tools used in DevWareDevWareX.
To hide or display the Toolbar, choose Toolbar from the View menu (ALT-V, T).

DetectDetect Devices - same action as "File→Detect Devices".  Find all sensors attached to the PC.

Info

Open or close the Info Dialog. The Info Dialog(See 2.2.5) contains an information window, Display Format choices and the current Mouse Selection choice.

 <F2> or <Ctrl-I>

Control

Open or close the Sensor Control Dialog(See 2.2.4). This set of pages gives access to a variety of image sensor registers through a user friendly interface.

 <F3> or <Ctrl-S>

Preset

Open or close the Preset Dialog(See 2.2.6). This dialog can be used to load or save the current state of the sensors (registers and color pipe settings).

 <Ctrl-P>

Register

Open or close the Register Dialog(See 2.2.7). The Register Dialog allows the user to read and write registers on the image sensor.

 <F4> or <Ctrl-R>

WarnOpen or close the Register Overwrite Dialog.  User Guide is here.

Log

Open or close the Register Log Dialog(See 2.2.8). This dialog logs sensor register writes.

 <Ctrl-L>

Graphs

Open or close the Analysis Dialog(See 2.2.9). The Analysis Dialog displays a graphical interpretation of a selected area of the display.

 <F5>

Magnify

Open or close the Magnifying Glass(See 2.2.10).  Allows user to magnify a section of the display window.


Image

Opens the Image Navigation(See 2.2.11) window.  Useful for navigating an image whose output size is larger than display area.


Watch

Opens the Watch Dialog(See 2.2.13) that allows the user to monitor volatile registers by re-reading them at a set time period.


Options

Opens the Options Dialog(See 2.2.15).


Play

Start displaying the image stream.


Pause

Pause the image stream.


Stop

Stop displaying the image stream.


Reset

(Soft) Reset the sensor to the power-on-defaults. This option loads the [reset] section from the appropriate .ini file.
Note: After resetting the sensor the user should re-load the default register settings by clicking the 'Init' button on the toolbar.


Init

Load the initialization register settings for the sensor. The register settings can be found in the [Demo Initialization] section from the appropriate .ini file.


Full Auto

Enable the default software color processing options.
Note: For Bayer sensors only.


Preview

Toggle the sensor between Preview (viewfinder), snapshot mode, and for sensors that support it video mode via a pull-down.
Note: Typically not supported for VGA size and smaller sensors.


Grab

Capture the displayed sensor image to hard disk or cancel an image capture.

 <F9>

LockFor sensors that support it,  simulates half-press of a camera shutter to lock auto-functions such as AE, AWB, and Auto Focus.

Snapshot

Capture the "full resolution" image to hard disk or cancel an image capture.
For sensors that support them, there is a pull-down where features such as SnapShot-and-lock, Zero shutter lag, and Snapshot Over Video can be demonstrated

 <Ctrl-F9>

Record

Records the image stream to hard disk.
Note: The video is uncompressed and will take significant hard disk space. This mode is for characterization only.


A Power-Point remote clicker's page-down and page-up buttons can be to start/stop recording when the PC is equipped with the IR interface.

 <F8> or

page-down = record start

page-up =
record stop

In

Zoom in on the displayed image.
Note: Zooming beyond 2x might not be supported by your graphics adapter and could lead to image artifacts and potentially to program instability.

 <F10>

Out

Zoom out on the displayed image.

 <F11>

Full

Displays the image in a full screen mode. This feature supports the following standard display modes:
640x480, 800x600, 1024x768, 1280x1024, 1600x1200 and 2048x1536
If the image from the sensor is not one of these sizes, the full screen mode will use the next larger size and fill in the extra area with black pixels. If the image is larger than the maximum size supported by the display device, it will shrink the image to fit. To return back to windowed mode, hit any key or click the mouse.

 <F12>

Bug

Generates a bug report that collects information directly related to the camera setup which is useful for debugging.


Home

Opens the ON Semiconductor homepage (http://www.onsemi.com/) in your browser.


...

Anchor
Bookmark11
Bookmark11
Anchor
_Toc372623589
_Toc372623589
2.2.3 Display

Image RemovedImage Added
This area is where the sensor images are displayed.
If an image is not displayed here (when expected), please refer to the troubleshooting(See 2.2.17) pages.

...

Images and Videos can be loaded for viewing, either by drag-and-drop method, or via the "File" menu via "Open Image or Video File".
Most image and video types can be viewed, including 32-bit BMP file format. See the Sensor Control dialogs of "Image Save Options" and "Video Record" for specifics.

Use the mouse wheel to zoom in, including to the maximum zoom level to see each pixel value:

Image Added

Anchor
Bookmark12
Bookmark12
Anchor
_Toc372623590
_Toc372623590
2.2.4 Control Dialog (Sensor Control)

...

HDMI Output 
For Demo3 only, enable/disables the HDMI output port. 
Focus Assist 
SW implementation of a focus score.  This "score" is a relative value, having no meaning other than a higher value indicates a crisper image focus.

The focus score is calculated as;

...

For "'Raw Bayer Color - Sensor Output", disable all DevWare DevWareX ColorPipe options.


Bayer Bypass/SW FRF Advanced 
This page implements a Flat Region Filter using Sigma, Edge, and Chroma thresholds.. 
Bayer Bypass/SW Green Balance 
This page allows the user to enable Green Balance Correction for the DevWare DevWareX SW ColorPipe and adjust Highlights and Shadows.
Bayer Bypass/SW Black Color Kill
This page allows the user to enable Black Color Kill for the DevWare DevWareX SW ColorPipe and adjust its thresholds.

...

These sensor control pages are only displayed for Bayer sensors. For example, the: A-0360, A-0366, A-1300, A-1310, A-2010, A-3100, etc. For the most part, they control software image processing algorithms in DevWareDevWareX.
Note: The available sensor control pages and features depend on the type and version of the image sensor.

Anchor
Bookmark14_DataInterpretation
Bookmark14_DataInterpretation
Data Interpretation Page
This page gives some control over the demosaicing algorithms that are used to convert the bayer image into an RGB color image.

...

These sensor control pages are only displayed for the AP010x Companion Chips. Note: only the differences between the AP010x page and the SOC page are listed - SOC Sensor Control Pages(See 2.2.4.4).
 
Hue PCR
This page gives some control over the Hue and StaturationSaturation. Select a rectangular region, wait for ROI sampleing to complete, and then adjustments can be made.
 
Gamma Curve
A custom Gamma Curve can be set via interpolation between the user-supplied 32 points for the X axis, and then adjustment of the Y axis.
 

Anchor
Bookmark15_Exposure
Bookmark15_Exposure
 
Color Kill
Adjustments to Color Kill can be made for the 3 zones using SNR and/or Gain.
 
Zoom Pan Control page
Available on on AP0101AT/CS, controls for sensor readout window and image reduction.

...

There are two distinct modes of still capture. In the Current Displayed Image mode the still capture only freezes the currently displayed image and lets you save it to a file. No sensor registers are affected.
In the Full Resolution Image mode DevWare DevWareX will perform a still capture procedure on the sensor. It could involve changing the image size, using global shutter mode, activating a flash lamp and so on. On an SOC it would involve activating the still image sequence on the sensor.

Still Image Format

For 20-bit depth, each pixel occupies 4 bytes, stored LSB first. The pixel value is in the 20 low bits.
For compressed formats, our software by default expands the pixels before saving the RAW file, so the RAW file has linear data.

2-byte covering 12-bit words:   (1 2 3 4   5 6 7 8) (9 10 11 12    0 0 0 0)
4-byte covering 20The software is transport-independent and supports parallel, HiSPi, and other interface types that don't even have a byte-wise representation.
MIPI is byte-wise, but the FPGA on the Demo3 parses the MIPI stream and unpacks the pixels. There is no way to get the MIPI stream exactly as it comes from the sensor.

RAW still files are always 8-bit, 16-bit or 32-bit per pixel. If the bit depth is not one of those values, then the smallest format big enough to hold the data is chosen and the data is in the least significant bits
This is how the data normally comes across from the device driver, and also has the advantage that it's easy to read with various software libraries and tools (Matlab, numpy, etc.).

For 20-bit depth, each pixel occupies 4 bytes, stored LSB first. The pixel value is in the 20 low bits.
For compressed formats, our software by default expands the pixels before saving the RAW file, so the RAW file has linear data.

2-byte covering 12-bit words:   (1 2 3 4   5 6 7 8) (9 10 11 12    0 0 0 0)
4-byte covering 20-bit words:   (1 2 3 4   5 6 7 8) (9 10 11 12    13 14 15 16) (17 18 19 20    0 0 0 0) (0 0 0 0    0 0 0 0)

Snapshot Page
Select various options related to still image capture. Note that "Average into One Frame" does not work with JPEG output format.  The Average is pixel-wise temporal mean.

Anchor
imagesaveoptions
imagesaveoptions
Image Save Options Page
This dialog is used to set the various image save options that are available.
The "Save Options" selection allows the user to select the type of data to be written to files. Raw Data is the unprocessed data coming from the sensor, which will be in the format the sensor is outputting, for example Bayer or YCbCr data. The Processed Data is RGB output data which has been converted from Bayer or YCbCr by DevWareDevWareX. The image will also include any of the image processing pipeline that has been enabled. The Processed Data can be saved in either a 24bpp Bitmap file or 48bpp TIFF file. By default the register information is saved in the accompanying .TXT file.
Also available are the options on where to save the images. Note; if both "Auto File Name Increment and Save" and "Hold Still Image in Main Window" are disabled, the "Grab" and "Snapshot" will not be able to actual provide images to save.
After a Still Image is captured, the "Filmstrip" dialog appears if the "Hold Still Image in Main Window" option is selected. This dialog shows thumbnails of the captured image(s). The user can then right-click on the image for various options, including opening the image for view, saving the image, and selecting the type of image.
"Save Mouse Selection Rectangle Only"; only the saved image will show the rectangle-only - the filmstrip will show the full image.

Note: Overlays (Watch and/or Embedded Data) will not appear on a .raw image.  Instead, they will appear on RGB-type image formats.

Reg Capture Page
This advanced feature allows the user to record the state of specific registers when performing a still image capture. A single register or a range or registers can be selected at once and added to the list. Multiple entries can be added to the list and each can be grouped into custom named categories.
Normally, when the Capture button on the Toolbar(See 2.2.2) is pushed and the "TXT (registers)" option is checked on the Save Options page a "capture####_info.txt" file is created. This file contains a variety of information, among which is the entire sensor register state at the time of the capture. For some purposes this may be more information than is necessary. The Reg Capture page allows the user to record only the register states they are interested in during the capture and simplifies subsequent locating or viewing within the .txt file.
Reg Capture appends any user defined categories to the end of the .txt file. To ease viewing and reduce the filesize, the user can remove the full register state dump. Expand the General category in the list box and uncheck the "All Registers" entry. By default this option is enabled (checked).


Anchor
videorecordpage
videorecordpage
Video Record Page
To capture a video stream press the Record button on the Toolbar(See 2.2.2).
NOTE: If Capture to RAM is unchecked, video is streamed directly to disk. The performance will depend on the speed of the hard disk and could result in dropped frames.
NOTE: The video formats are uncompressed and will take a significant amount of hard disk space.
NOTE: If Preview is disabled then the Color Pipe functions are skipped while live frames are accumulating. There will be no AE, nor any other Color Pipe processing.
You can save data in MPEG-4, AVI (2GB limit), WMV, or RAW format. RAW format requires no image processing and usually takes less disk space. If you don't have a compatible WMV codec installed, you'll be prompted with a URL to download one when you select that format. 
You can also save data as "PNG Raw Files" or "PNG RGB Files", which is the ability to save a video as a sequence of PNG files in either Raw or RGB format. Note that Raw only supports Bayer or similar (not YCbCr).

You can use WMV instead of AVI for unlimited file length. DevWare DevWareX does not use compression with AVI. Usually the codec is just RGB-24. WMV is compressed in software.

The compression quality for MPEG-4 or WMV recording can be controlled with the "VidCap Quality" STATE variable.

...

  • There is a frame rate value stored in the wmv file. There is a check box and numerical entry on the Sensor Control -> Video Record dialog page where you can provide a frame rate to put in the file. If that is not checked DevWareX uses the Display FPS.
  • But that value comes from before recording started. During recording there could be considerable disk overhead or compression overhead so that the actual frame rate during recording is lower than it was before recording started. In that case the frame rate in the file will not match the actual frame rate of the recording.

The compression quality for MPEG-4 or WMV recording can be controlled with the "VidCap Quality" STATE variable.

Recording to H264 converts the original stream to RGB, and encodes to H264. If the original stream is H264 then it will do a decode and encode.
If the original stream is H264 and you want to just record that directly then record as RAW.

...

The end of each image row is padded up to the next byte boundary if needed.
Note: to record without compression, on Sensor Control -> Data Interpretation -> Decompress select 'Not compressed'.Recording high resolution video can be challenging. For short clips you can capture to RAM so the disk performance will not be a bottleneck. When recording to disk you will get the best recording frame rates by recording in RAW format and turning off preview while recording.
RAW files will play back in DevWareVideo Record, unselect "Packed".

If the sensor supports Companding, use Sensor Control → Video Record "Decompand" to enable/disable it.

How to record Recording high resolution video without dropping frames

  • Record to RAM - usually your best option.
    • Under "Video Record" select "Record to RAM on the PC, then save to file".

    • You can then choose one of the 3 options on what to do when RAM is full - most useful option is "When RAM is full, write to disk and stop".

    • To find the maximum amount of RAM available, enter "Resource Monitor" in the search bar.
      At the bottom is "Available", in MB. It is recommended to use no more than 80% to 90% of this value in the "RAM buffer size" field.

  • A PC with an SSD may be able to record at-speed to a file. When recording to a file you will get the best recording frame rates by recording in RAW format and turning off preview while recording.

Some additional helpful info;

  • RAW files will play back in DevWareX, but will need to be converted to AVI to be imported into other applications. You can use

...

  • DevWareX as a RAW to AVI file converter. Load the RAW file in

...

  • DevWareX and verify that the image looks correct. On the Video Capture dialog page select AVI recording format and turn off Capture to RAM. Click the Stop button on the Toolbar(See 2.2.2). Click the Record button on the Toolbar(See 2.2.2).
  • The "Frame rate" listed in the info.txt file (RAW only) is the rate displayed on the Info Panel "FPS (Display)".
    A specific frame rate can be set via Sensor Control / Video Record "Specify playback frame rate", or via the INI file using the STATE commands "VidCap Auto Play FPS" and "VidCap Play FPS".
  • “Specify playback frame rate”; DevWareX video playback speed is not precise.
  • MPEG-4 requires at least 20 frames to be recorded. 


Single Button Image Capture
To enable the ability to perform a single-button image capture, do the following;- On the "Snapshot" page, enable "Camera Sound Effects". - On the "Image Save Options" - Use <F9> (for a "Grab") or <Ctrl-F9> (for a "Snapshot") to capture an image with a single button.

Anchor
Bookmark19
Bookmark19
2.2.4.7 Diagnostic Pages

Noise Measurement Page and Noise vs. Exposure

User Guide can be found here.

The Noise Measurement tool runs a series of noise analysis computations, and reports signal levels and different kinds of noise measurements.
After the analysis completes, the results are displayed here in plain text, tab-separated format.

...


Anchor
Bookmark19_WatchPage
Bookmark19_WatchPage
Anchor
Bookmark19_FuseIDPage
Bookmark19_FuseIDPage
Fuse ID Reader Page
The Fuse ID Reader page is used to get and save the Fuse ID information for each sensor, by reading register combinations specific to each sensor and saving this information.
 
DEMO2X / DEMO3
Gives you access and control to features of the baseboard. - The onboard oscillator can be set via the XMCLK field.- The attached device's wired reset/power/shutdown controls are available in the "Sensor" field.- The "Sensor Data Acquisition" field controls various aspects of clocking and pixel data.- Check "Update" at the bottom to see the current sensor output. This can help you diagnose problems when DevWare can't capture images from the sensor.

...

The Info dialog appears at the left edge of the DevWare window and displays information about the image sensor, the frames displayed and the mouse position. Additionally, it has list box controls to change the mouse selection area (for use with the Analysis Dialog(See 2.2.9)) and to select between multiple sensors (only appearing if more than one sensor is attached).
Property fields:

...

Sensor

...

The ON Semiconductor Imaging sensor being used.

...

Part number

...

The ON Semiconductor part number for this sensor.

...

Sensor version

...

The version of the image sensor.

...

Sensor type

...

Either 'Bayer' or 'SOC' sensor.

...

Software:

...

Build name

...

The version and type of build (either Release or Beta).

...

Build version

...

The full version number (major.minor.revision.build) of the DevWare application.

...

Build date

...

Date the software was compiled. (MM/DD/YYYY)

...

Demo Board:

...

Type of Demo board being used (for example: DEMO2X or DEMO3).
Note: The FPGA version is displayed in parentheses.

...

Firmware

...

The version of the Firmware code on the Demo board.

...

Array Clock

...

The oscillator frequency being used (in MHz).
Note: This value can be modified by the user through the Options Dialog(See 2.2.15).

...

Pixel Clock

...

The pixel clock output as calculated by DevWare based on the specific configuration of the attached device.
It is intended to be the pixel rate at the sensor output.
DevWare has different ways of deriving clocks from each other.  In most cases, array clock was derived from external clock, and then pixel clock was derived from array clock.

Array Clock is nominally the sensor array clock. It's the clock used to calculate row time, exposure time, etc.
Pixel Clock is PIXCLK for the parallel interface, or the pixel rate. There is also Input Clock which is the clock input to the sensor.

Normally, the clock rates are re-measured when a PLL register is changed. Depending on the demo kit configuration, it may not be possible to measure the clocks from software. Demo2X can measure PIXCLK if the sensor is streaming in parallel mode. Demo3 can measure Input Clock if it is hooked up to the Demo3 clock sense line. Once one of the clocks is measured, the other two can be calculated from the PLL settings.

The clock speed on the Options dialog sets the Array Clock value (in case DevWare can't measure it), and Pixel Clock and Input Clock will be automatically calculated according to the PLL settings.

...

Width

...

The pixel width of the displayed sensor image.

...

Height

...

The pixel height of the displayed sensor image.

...

Format

...

The current sensor image format (for example 'YCbCr', 'Bayer 8', 'Bayer 10', etc.).

...

Frames

...

A frame counter that gets increased for each displayed sensor image.

...

Dropped frames

Dropped frames are possible under the following circumstances:

...

Sensor Advanced

This dialog allows for override of settings that DevWareX usually determines on its own via reading sensor register settings.

  • Sensor; these check-boxes control hard-wired lines from the Demo3 to the sensor; Power, Reset, and Shutdown.
  • Sensor Clock Speed; sets the Input clock speed from Demo3 to sensor headboard (assuming the headboard is jumpered for external clock), and Array clock.
    • Use the "Apply" to set the values, and "Detect" to display the current settings.
  • Sensor Base Address; use "Detect" to discover the current I2C value, and the pull-down and then "Apply" to assign a new value (where applicable).
  • Color Filter Array (CFA); displays the current CFA, and use the pull-down to force the DevWareX ColorPipe to use this CFA.
  • Sensor Output; use "Detect" to discover the current width/height and pixel format, and "Apply" to set new ones.
  • Check-boxes; use these to change the pixel order/format.

DEMO3

Gives you access and control to features of the baseboard. - The onboard oscillator can be set via the XMCLK field. The "Image Buffers" select the type of buffering used by the Demo3. And "GPIO Pins" allows the enable / disable and level (on/off).

Serial Receiver

This dialog controls the various settings of the image sensor output format to the Demo3.  The actual controls are self-explanatory as it assumes the user knows these advanced settings.

Anchor
Bookmark20
Bookmark20
Anchor
_Toc372623591
_Toc372623591
2.2.5 Info Dialog

The Info dialog appears at the left edge of the DevWareX window and displays information about the image sensor, the frames displayed and the mouse position. Additionally, it has list box controls to change the mouse selection area (for use with the Analysis Dialog(See 2.2.9)) and to select between multiple sensors (only appearing if more than one sensor is attached).
Property fields:

Sensor

The ON Semiconductor Imaging sensor being used (only appears if value is different than "Part Number").

Part Number

The ON Semiconductor part number for this sensor.

FamilyWill appear when a sensor is a member of a "family" of sensors (e.g., Hyperlux).

Sensor version

The version of the image sensor.

Sensor type

Either 'Bayer' or 'SOC' sensor.

Die Temp.Die Temperature.
InterfaceSensor output type; Parallel, MIPI, HiSpi, etc.

Software:


Build name

The version and type of build (either Release or Beta).

Build version

The full version number (major.minor.revision.build) of the DevWareX application.

Build date

Date the software was compiled. (MM/DD/YYYY)

Demo Board:

Type of Demo board being used (for example: DEMO3).
Note: The FW version and FPGA version is displayed in parentheses.

Input ClockThe sensor's input clock (in MHz).

Array Clock

The oscillator frequency being used (in MHz).
Note: This value can be modified by the user through the Options Dialog(See 2.2.15)

and enable 'Debug Mode (show dropped frames)'

.

FPS (Sensor)

The computed number of Frames Per Second that the sensor is running at based on register settings and oscillator (see Clock above) value.
Note: SOC sensors dynamically change the frame rate for exposure purposes. To update the FPS number click the 'Refresh' button at the bottom of the main Sensor Control dialog(See 2.2.4).

FPS (Datalink)

The number of Frames Per Second that the camera sends to the host computer via USB (or other data link). This number can be influenced by the speed of the computer, or the host controller and drivers.

FPS (Display)

The number of Frames Per Second that are displayed on the computer. A camera frame is first converted from its native format (see above) to a 32bit RGB image and finally converted to the display adapter's resolution (preferably also 32 bit). Software image processing can slow down the display frame rate. The display frame rate is also affected by the host computer's display drivers. The Accelerated selection on the Options(See 2.2.15) dialog can help.

Cursor pos

The mouse cursor position when the mouse is over the display area. Expressed as a positive (width, height) value relative to the upper-right most pixel (0,0).

Raw Data

The unprocessed sensor data at the mouse cursor position. For SOC sensors the data is separated into Y, Cb, and Cr values. For Bayer sensors there is a single data value, with the Bayer color pattern position indicated in parentheses (R, Gr, Gb, or B).

R: Output

The value of the Red component of the displayed image at the mouse cursor position.

G: Output

The value of the Green component of the displayed image at the mouse cursor position.

B: Output

The value of the Blue component of the displayed image at the mouse cursor position.

Mouse Selection (used in conjunction with the Analysis Dialog(See 2.2.9)):

...

Off

...

No area selected. The whole image is used for analysis.

...

Rectangle

...

Only the selected rectangle is used for analysis (typically used with the analysis-histogram graph).

...

Column

...

Only the selected column is used for analysis (typically used with the analysis-intensity graph).

...

Row

...

Only the selected row is used for analysis (typically used with the analysis-intensity graph).

...

Point

...

Only a single point is used for analysis (typically used with the analysis-noise graph).

Press and hold the left mouse button (while over the Display(See 2.2.3) area) to change the selection area.

...

Output Clock

The pixel clock output as calculated by DevWareX based on the specific configuration of the attached device.
It is intended to be the pixel rate at the sensor output.
DevWareX has different ways of deriving clocks from each other.  In most cases, array clock was derived from external clock, and then pixel clock was derived from array clock.

Array Clock is nominally the sensor array clock. It's the clock used to calculate row time, exposure time, etc.
Pixel Clock is PIXCLK for the parallel interface, or the pixel rate. There is also Input Clock which is the clock input to the sensor.

Normally, the clock rates are re-measured when a PLL register is changed. Depending on the demo kit configuration, it may not be possible to measure the clocks from software. Demo2X can measure PIXCLK if the sensor is streaming in parallel mode. Demo3 can measure Input Clock if it is hooked up to the Demo3 clock sense line. Once one of the clocks is measured, the other two can be calculated from the PLL settings.

The clock speed on the Options dialog sets the Array Clock value (in case DevWareX can't measure it), and Pixel Clock and Input Clock will be automatically calculated according to the PLL settings.

Width

The pixel width of the displayed sensor image.

Height

The pixel height of the displayed sensor image.

Image Type

The current sensor image format (for example 'YCbCr', 'Bayer 8', 'Bayer 10', etc.).

Size (bytes)Size of image data, in bytes.

Frames

A frame counter that gets increased for each displayed sensor image.

Dropped frames

Dropped frames are possible under the following circumstances:

  • The application couldn't determine the end-of-frame because of a change in the data flow (this is not a sensor issue).
  • The image data is sent faster then the computer can handle. This can happen on slower PC's/laptops or when other applications are slowing down the computer.
    To view the dropped (incomplete) frames regardless, go to the Options Dialog(See 2.2.15) and enable 'Debug Mode (show dropped frames)'.

FPS (Sensor)

The computed number of Frames Per Second that the sensor is running at based on register settings and oscillator (see Clock above) value.
Note: SOC sensors dynamically change the frame rate for exposure purposes. To update the FPS number click the 'Refresh' button at the bottom of the main Sensor Control dialog(See 2.2.4).

FPS (Datalink)

The number of Frames Per Second that the camera sends to the host computer via USB (or other data link). This number can be influenced by the speed of the computer, or the host controller and drivers.

FPS (Display)

The number of Frames Per Second that are displayed on the computer. A camera frame is first converted from its native format (see above) to a 32bit RGB image and finally converted to the display adapter's resolution (preferably also 32 bit). Software image processing can slow down the display frame rate. The display frame rate is also affected by the host computer's display drivers. The Accelerated selection on the Options(See 2.2.15) dialog can help.

Cursor pos

The mouse cursor position when the mouse is over the display area. Expressed as a positive (width, height) value relative to the upper-right most pixel (0,0).

Raw Data

The unprocessed sensor data at the mouse cursor position. For SOC sensors the data is separated into Y, Cb, and Cr values. For Bayer sensors there is a single data value, with the Bayer color pattern position indicated in parentheses (R, Gr, Gb, or B).

R: Output

The value of the Red component of the displayed image at the mouse cursor position.

G: Output

The value of the Green component of the displayed image at the mouse cursor position.

B: Output

The value of the Blue component of the displayed image at the mouse cursor position.

Mouse Selection (used in conjunction with the Analysis Dialog(See 2.2.9)):

Off

No area selected. The whole image is used for analysis.

Rectangle

Only the selected rectangle is used for analysis (typically used with the analysis-histogram graph).
Note: You can do an Intensity plot in any direction.

Column

Only the selected column is used for analysis (typically used with the analysis-intensity graph).

Row

Only the selected row is used for analysis (typically used with the analysis-intensity graph).

Point

Only a single point is used for analysis (typically used with the analysis-noise graph).

Press and hold the left mouse button (while over the Display(See 2.2.3) area) to change the selection area.

Anchor
Bookmark21
Bookmark21
Anchor
_Toc372623592
_Toc372623592
2.2.6 Preset Dialog

 This dialog can be used to load or save the current state of the sensor registers and color pipe settings. This information is stored within an .ini file which is loaded for each version of the sensor. For example, the file for the AR0544CS-REV1 would be located in C:\Aptina Imaging\apps_data\AR0544CS-REV1.ini.

All sensors have a 'Demo Initialization' preset. Bayer Sensors typically have a 'Color Processing ON' and 'Color Processing OFF' Preset as well.
INI files are plain text and can be edited by the user.

See the INI File Users Guide for more information about ini files and the command syntax.

Image Added

INI file and optional Initializer: Location of main INI file on first line, and optional location of Initializer file (for those sensors with separate Python-settings files).

Preset Actions: various actions available for the loaded INI file.

  • Open: open an additional INI file.  Same operation as available in "File / Open Additional Presets ..."
  • Edit: edit the INI file, using the edit application associated with ".ini" files.
  • Edit Initializer: edit the Initializer file (when present), using the edit application associated with ".py" files.
    • Note: notepad.exe will be used if no edit application is associated with ".py" files.
  • Reload: reread the INI file - to be used if "Edit" or "Edit Initializer" have modified their respective files.
  • Default: go back to the default INI file - the INI file associated with the loaded SDAT file.
  • Load: will load and run the Preset highlighted in the "Presets" window.
  • Rename: rename the selected Preset.
    • Note that the INI file is automatically saved, but does not need to be Reloaded.

Preset Name Search: enter search terms. Only preset names matching all terms will be shown.

Presets: displays all available Presets.  Note that Dialog Settings "Options..." can be used to show "Hidden" presets.

Dialog Settings: various settings that are available.

  • Warnings: Show the Register Overwrite Warnings dialog. Same operation as the "Warn" Toolbar.
    • This will check for accidental overwrite of OTPM-trimmed registers, or other inappropriate register values.
    • Checking this report should be part of the verification of any new mode presets.
  • Options...: show "Hidden" presets.
  • Guide: opens the on-line INI Users Guide.

Anchor
Bookmark22
Bookmark22
Anchor
_Toc372623593
_Toc372623593
2.2.7 Register Dialog

...

Intensity
The Intensity graph displays the intensity (on the vertical-axis) of each of the selected pixels (horizontal-axis). Right-click on the graph for more options. To save the intensity data to a file (tab-separated text) right-click on the graph and select Save Graph Data As.... The Intensity graph only works when you use the Mouse Selection tool to select a Row, Column or Rectangle (for use with diagonal measurement).
The X-axis represents the actual pixel being measured.  Row and Column Means require a Rectangle (or Off to use the entire image as the Rectangle).
Note; when using Row on a Bayer image, two rows are used so all four channels.
It plots an even rows and an odd row, so if on on even row it adds the row below, and if on an odd row it adds the row above.

Histogram
The Histogram collects the total amount of pixels (vertical-axis) for each of the possible intensity values (horizontal-axis) for each of the color channels. The histogram is taken over the currently selected area and works best for a small rectangular selection(See 4.4).
Right-click on the graph for more options. To save the histogram data to a file (tab-separated text) right-click on the graph and select Save Graph Data As....
When the histogram is being displayed, if you right-click on the graph and select Show Control Window the following Analysis Graph Controls are available.
By default the histogram data is displayed in Combined RGB mode. The Analysis Graph Controls can be used to display a luminance graph as well. When displaying a luminance graph the user has the option to display additional data characteristicswell. When displaying a luminance graph the user has the option to display additional data characteristics.

The graph calculates approximate mean from the histogram. So the precision is limited by the size of the histogram bins. That's why it says " ~161 ". Likewise for the other statistical calculations on the graph.

Noise
The Noise graph shows the intensity (vertical-axis) of a single pixel for each frame for all color channels. The old values remain so an intensity-over-time (horizontal-axis) graph appears. This display wraps around and shows approximately 640 time slices. The text at the top display computed temporal SNR in dB. (If there is no fluctuation in the data, the readout shows 0.0.)
Additional Data displayed;

...


Vectorscope
The Vectorscope graph shows the distribution of the chrominance signal in the selected area. You will need to aim the camera at a color reference chart.
NOTE: DevWare DevWareX only uses 8-bit output for Bayer Sensors by Default. To switch to 10-bit output, go to the 'Sensor Output' Bayer Image Sensor Control Pages (See 2.2.4.2)

...

  • By right-clicking on a register (or bitfield) item in the Register dialog, then choosing "Add to Watch" from a popup menu.
  • By right-clicking on a register (or bitfield( item in the Log dialog, then choosing "Add to Watch" from a popup menu.
  • By using the Save/Load button to load a previously save watch list. DevWare DevWareX remembers your watch list when it exits and restores it when it starts up again.

Record to csv File
During monitoring, user can also record register values to a csv file.  The number of entries per second is sensor frame rate.
 
Save/Load (Watch REG Preset Dialog)
The Watch REG Preset Dialog can be used to load a "watch" preset defined in an .ini file or to create a new "watch" preset to an .ini file. This allows the user to save and load the watched registers between sessions. The default .ini file used for the presets will be used for the watch presets. Another .ini file can be selected using the Browse button. All the preset names in list box will be pre-appended with "Watch REG:" in the .ini file to differentiate them from standard presets.

Watching Registers on the Demo3
Watch assumes register addresses refer to the sensor.
You can still monitor it on the Watch dialog using the Python function feature.

On the Watch dialog click Non-Register…, click Next, for def put MipiFrameCRC, in the box put

   return demo3.MipiFrameCRC.value

(including the leading spaces).  Then click Test Function, click Finish.

Anchor
Bookmark29
Bookmark29
Anchor
_Toc372623600
_Toc372623600
2.2.14 Embedded Data Viewer

...

Most fields have "Tool Tips" that can be scrolled-over for usage and INI file information.

Image Removed

...

.

Image Added

  • Display: selects the display format - for remote display of DevWareX select "No DirectX" and zoom increment.
  • Log FIle : enables various types of logging output, from DevWare DevWareX internal errors to USB traffic.
  • Sensor Base Address : allows the detected I2C address to be overridden or detectedWarning Dialogs: reset just the Warning Dialogs setting (re-enables them). Use "View→Warning Log" to see all warnings.
    • Detect Bad Frame Sequence: enable/disable the all-frame dropping warning message.
  • Debug Settings : enables debugging of displayed images.
    • Show Dropped Frames : very useful in displaying images that aren't in the expected format, or corrupted frames such as JPEG.
  • Sensor Output : allows the detected width/height/format to be overridden or detected.
  • Display : selects the display format - for remote display of DevWare select "No DirectX".
  • Miscellaneous : various settings that could be enabled or disables as seen in the figure above.Warning Dialogs : renables various warning messages that were disabled when their associated dialogs appearedin the figure above.
  • Reset All : resets all settings to their defaults.

...

When the program does not behave the way intended, or you experience problems that are not covered in the help files you may wish to file a bug report(See 2.2.18) .
Check to see if any of the following sections help with the problems you encounter.
I have problems starting the application and see one of the following warning message boxes:
Image RemovedImage Added
-> Check if the USB drivers are installed properly. Refer to the driver installation document under "Start>All Programs->Aptina Imaging->Docs->User Guides->USB Drivers User Guide".
--> Check if the cables are attached to the image sensor properly. If the image sensor worked before, unplug-and-plug the cables and try again.
Image RemovedImage Added
--> Check if the application is started from the same place that holds the sensor_data directory (holding the sensor data(See 4.5) files)
The application starts without errors, but there is no image:
--> Some register settings might lead to stop the sensor from sending valid data. Quit the application and reset the sensor by unplugging it and plugging it back in.
My frame rate is really low:
--> The amount of data that is being processed is quite significant or a lot of image processing function are turned on. Reduce the size of the image on the Output Size or Context page of Sensor Control. On the Options dialog, select the Accelerated Display option. Turn off extra image processing. 
When setting registers the application freezes up:
 -->Changing registers on the image sensor might lead to changes in the data flow resulting in unexpected lockups of the application. Terminate the application as best as possible and reset the sensor by unplugging it and plugging it back in.

...

  • If the trouble shooting(See 2.2.17) pages did not help solve the problem you are having you may wish to email a bug report as follows:
  • In DevWareDevWareX, go to the menu Help -> Bug Report or select the picture of the "bug" from the toolbar.
  • Provide as detailed as possible a bug description (mention bug symptoms like 'no image', 'distorted image', etc.)
  • Provide information on how to reproduce the bug (what registers did you change, what buttons did you press before the bug showed up, etc)
  • Copy the contents of the system information window to the clipboard by pressing the Copy to Clipboard button.
  • Start an email and paste (Ctrl-V) the clipboard contents of system information into the text portion of the email. Edit this information as you see fit, see the note below.
  • Send the email to Aptina-IMAGING_DEMO_BUGS@onsemi.com.com
      NOTE: The system information that is gathered to help us solve the problems you encountered consists of the following sections: Application version info, Camera info, Windows Operating System info, Processor info, USB Host Controllers info and Image Sensor Register settings. The application only gathers this information and does not send anything. Please look through the information and edit it as you see fit before emailing it.

    Anchor
    Bookmark34
    Bookmark34
    Anchor
    _Toc372623605
    _Toc372623605
    3. About ON Semiconductor's Developer Suite

    The following list provides details about folders of interest installed in C:\Aptina Imaging
    Folders:

    appsApplications that use specialized libraries

    apps_data

    .INI files for ON Semiconductor sensors

    board_data

    Data files for ON Semiconductor demo boards

    capture

    Storage location of DevWare DevWareX captured images

    DevWare
    DevWareXFiles specific to DevWareDevWareX.exe

    doc

    Documents, schematics, and BOM's

    driversUSB drivers and User Guide

    firmware

    Demo board firmware files

    flashtool

    Flash Tool for automotive products

    fpga

    Demo board FPGA files

    include

    Include files for imaging applications

    imageformatsImage format .dll files

    lib

    ON Semiconductor Imaging library (midlib) files

    Plugins

    DevWare DevWareX plug-in files

    samples

    Sample imagine application code

    sensor_data

    ON Semiconductor sensor data (.SDAT) files

    "Start Menu" Index
    Here is a list of folders and their contents, that are accessible from the Windows Start menu.
    Folders:

    Docs

    Start->All Programs->Aptina Imaging->Docs
    Links for all documentation and schematics.

    SDK

    Start->All Programs->Aptina Imaging->SDK
    Links provided to sample applications to help users develop their own imaging applications.

    Tools

    Start->All Programs->Aptina Imaging->Tools
    Links for tools such as HardwareUpdate, RegPoke, Flashtool, etc.)


    Anchor
    Bookmark35
    Bookmark35
    Anchor
    _Toc372623606
    _Toc372623606
    3.1 HardwareUpdate Tool

    This is a Window's application that updates the firmware and FPGA code on the ON Semiconductor Imaging baseboard (Demo2X or Demo3). The tool is located in: Start menu -> All Programs -> Aptina Imaging -> Tools .


    Usage and Tips

...

  • Connect two Aptina Imaging Demo cameras to the system. Make sure the cameras are recognized and the drivers are installed.
  • Launch SideBySide from the desktop shortcut. The application will automatically start two instances of DevWare DevWareX and size the display windows evenly. The initial startup takes a little more time than normal, but requires no user interaction. Please be patient.
  • All DevWare DevWareX toolbars and dialogs are hidden by the application. They can be manually re-enabled if access to a specific control is needed.
  • Selecting Quit from the SideBySide control bar will close all DevWare DevWareX instances, it is not necessary to close each one separately.

...

Play

Start displaying the image stream

Pause

Pause the image stream

Stop

Stop displaying the image stream

Reset

(Soft) Reset the sensor to the power-on-defaults. This option loads the [reset] section from the appropriate. ini file.
Note: after resetting the sensor the user should re-load the default register settings by clicking the 'Init' button on the toolbar or picking the 'Initialize' menu option below.

Initialize

Load the recommended register settings for the sensor. The recommended register settings can be found in the [Demo Initialization] section from the appropriate. ini file.

Full Auto

Enable the recommended software color processing options
Note: for Bayer sensors only

Preview mode

Toggle the sensor between preview (viewfinder) and snapshot mode.
Note: typically not supported for VGA size and smaller sensors  

Check Sensor

Re-evaluate the current state of the sensor. This can help you recover from a situation where DevWare DevWareX is dropping all frames.


Anchor
Bookmark40
Bookmark40
Anchor
_Toc372623611
_Toc372623611
4.2 File menu commands

Open Sensor Data File 

Open a specific sensor data (SDAT) file for the current sensor.

Open Image or Video File

Open an image file and display the image, instead of a sensor.

Recent Sensors / ImagesShow a list of the most recent SDAT and image files.
Refresh Register ListReopen a specific sensor data (SDAT) file for the current sensor(Using file browse).

Open Default Presets

Open an INI file as the default presets file. (same as the Browse... button on the Presets dialog).

Open Additional Presets

Open an INI file as an additional presets file. This INI file will not affect the dfault presets file, and it will not be used to specify the actions of the DevWare DevWareX toolbar.Refresh Register List

Reopen a specific sensor data (SDAT) file for the current sensor(Using file browse).

Probe for Devices

Re-run the device probe that will determine what sensor you have attached and automatically select the right SDAT file.

Capture Image

Capture the currently displayed sensor image to hard disk <F9 >.

Take Snapshot

Capture the sensor image to hard disk <Ctrl-F9 >.

Record Video

Record the image stream to hard disk Note: the video is uncompressed and will take significant hard disk space. This mode is for characterization only.

Exit

Exit the application. <Alt-F4>.

...

Help Topics

Offers you an index to topics on which you can get help.

Tutorial VideosPoints to our YouTube channel. The video support link is https://www.youtube.com/user/AptinaDeveloper/videos

Bug report

When you find a problem with this software, please file for a bug report by following the information in the Bug Report Dialog.

System DumpOpens system information in Bug Report pop up window.
Performance OverlayPerformance log is displayed as overlay on the image or view finder.
Performance DumpPerformance Dump is displayed as part of overlay
Check for updatesDisplays the latest DevSuite daily build that could be installed
Internet Home Page
Opens the page http://www.onsemi.com/

About

Version and copyright information.

...

This only occurs when you hide extra rows. In your table below the only case where you used the 'Hide' option is the right-most column, 'AR0220AT/hidden'. In all other columns you have not used the 'Hide' option, so the 'last row' is 'height' - 1.

Double-click "Mouse Selection" bar to open the dialog that allows setting of up to 8 unique mouse configurations.  Also see "Lock Mouse Selection", here.

Summary

Not using 'Hide' option: 'last row' = 'height' - 1
Using 'Hide' option: 'last row' = 'height' - number_of_hidden_extra_rows - 1

Whether the sensor outputs embedded data rows is different from whether DevWare DevWareX hides them.

Sensor

AR0132

AR0132

AR0220

AR0220

Emb. Data on

on

Off

On

On

Emb. Data hidden

Unhidden

Unhidden

Unhidden

Hidden

Height

964

960

980

980

Last row

963

959

979

947

Height - last row

1 (unhidden)

1 (unhidden)

1 (unhidden)

33

...

Displays the default presets file corresponding to the sensor connected7 Dialog and on the image sensor. <F4> or <Ctrl-R>Open or Close Register Data Sheet window containing register bit informationView sensordata

Toolbar

Show or hide the Toolbar(See 2.2.2).

Status Bar

Show or hide the Status Bar that appears along the bottom of the DevWare DevWareX main window. This bar may provide brief infomation about the currently selected feature, status of various Caps/Scroll/Num lock keys, etc.

 User User Toolbar

Show or hide User Toolbar below the menu bar.

User Toolbar 2Show or hide User Toolbar in the right side of DevWare DevWareX to enable adding desired shortcuts needed by user.
Plugins ToolbarShow or hide Plugins menu(See 2.2.1.1).
Toolbar LabelsShow or hide labels for the options in the toolbar.Default Presets
RulersShow or hide the pixel labels in the live video display.
Pixel Values in HexWhen fully zoomed-in in the live video display, show the pixel values in hex or decimal.

Info Dialog

Open or Close the Info(See 2.2.5) Dialog . This dialog contains Demo System information, display format choices and the current mouse selection(See 4.4) choice. <F2> or <Ctrl-I>

Sensor Control

Open or Close the Sensor Control(See 2.2.4) pages. This set of pages provides access to a variety of image sensor registers through a user friendly interface. <F3> or <Ctrl-S>

ColorPipeOpen or Close the ColorPipe dialog.  User Guide can be found here.

Preset Dialog

Open or Close the Presets(See 2.2.6) dialog. This dialog can be used to load or save the current state of the sensors (registers and color pipe settings). <Ctrl-P>

Register Dialog
 

Open or Close the Registerand color pipe settings). <Ctrl-P>

Register Dialog
 

Open or Close the Register(See 2.2.7) Dialog. This dialog allows the user to read and write registers on the image sensor. <F4> or <Ctrl-R>

User ControlCreate your own presets using a text editor, or various tools in DevWareX. User Guide can be found here.
Register All Access
(Peek & Poke)
Opens the Peek & Poke(See 2.2.12) dialog. This dialog allows the user to quickly read or write registers Register Data sheetby specifying specific addresses and values.
Register Overwrite
Warnings
Open or Close the Warn Dialog. User Guide can be found here.

Log Dialog

Open or Close the Register Log(See 2.2.8) Dialog. This dialog allows the user to view and log all the register changes that are happening. This could be useful when manipulating higher-level user interfaces on the Sensor Control pages. <Ctrl-L>Peek & Poke
 

Opens the Peek & Poke(See 2.2.12) dialog. This dialog allows the user to quickly read or write registers by specifying specific addresses and values.

Analysis Graphs

Open or Close the Analysis(See 2.2.9) Dialog. This dialog displays a graphical interpretation of a selected area of the display. <F5>

Magnifier

Open or Close the Magnifier(See 2.2.10) window. This feature allows user to zoom a desired section of the display area.

Image NavigatorOpen or Close Image Navigator Window.

Watch

Open or Close the Watch(See 2.2.13) Dialog. This dialog allows the user to add individual registers and track their value in real time.

Embedded Data ViewerOpens or Closes Embedded Data Viewer which could be used to log embedded data to a desired .csv file.

real time.

Captured ImagesOpens or closes captured images window showing the images captured in the particular instance of DevWare.
Python ConsoleOpens the Python console where commands could be entered.
Debug ConsoleOpens Debug console.
EEPROM PresetsOpens EEPROM Presets console.
Warning LogOpens the Warning Log Dialog.
Mouse Selection AreaOpens the Mouse Selection Dialog.  Allows for selecting up to 8 different mouse selection configurations.
View Sensor Data FileOpens the sensor data file for the connected sensor.

Zoom in

Zoom in on the display image. <F10>

Zoom out

Zoom out on the display image. <F11>

Full Screen

Switches the display into FullScreen Mode. To return back to windowed mode, hit any key. <F12 >

Options

Open or Close the Options(See 2.2.15) Dialog.

Center All DialogsUse when switching between different sized monitors and dialogs are positioned off the screen.

Open or Close​

Opens the Peek & Poke(See 2.2.12) dialog. This dialog allows the user to quickly read or write registers by specifying specific addresses and values​

Anchor
Bookmark47
Bookmark47
4.7 Gray Checker

...

Fig.1 demonstrates Log(B/G) vs. Log(R/G) diagram for each GretagMcBeth color squares. Series number corresponds to McBeth color square number. B/G and R/G ratios were calculated for row data received after applying unity analog and digital gain to each color channel at four different color temperatures covering temperature range from 2800K to 6500K. Series 19-22 were received from gray McBeth chart zones and define white-points aria.

Image Removed

Fig.1 Log2(B/G) vs LOG2(R/G) diagram for GretagMcBeth colors received for A-3120 sensor.

Image Added

White-points aria has to be specified for certain sensor and every pixel considering for WB statistic has to be tested for belong to the white aria. The given document describes method estimating distance from any point in 2-D space (current pixel) to white-points curve specified in this space by piece-wise linear curve. The given method is independent from type of coordinates and does not require a lot of resources for implementation.

...

Copy Image

Copies image to clip Board.

Edit Image in Aptina Viewer

Opens the image in Aptina Viewer to allow editing.

Edit Raw Image in Aptina Viewer

Opens the Raw image in Aptina Viewer so that it can be Edited.

Search Registers

Opens the Search Registers window to search for desired registers.

Edit Default Presets File

Opens the preset file(corresponding to the sensor connected) in not pad to allow editing.

4.10

...

DevWareX Register "Spying"

DevWare DevWareX spies on register writes, and if something that affects DevWare DevWareX changes, such as image format, then DevWare DevWareX adjusts automatically.

This includes writing to the attached device, any auxiliary boards (e.g. Dual Lane MIPI), and/or the basebase (Demo2X or Demo3).

...