- In Manual mode, the slider bar allows quick movement of the actuator.
- When the slider bar indicator is selected, left and right arrow buttons will move the actuator 1 value, and page up/down move the actuator by 20 values.
- A position can be entered directly in the "Slider Pos" field, and then used with either "Return" or selecting "Trigger".
- Sharpness score; displays the calculated sharpness score of the image - the higher the number, the more in-focus the image.
- Displayed during Manual and other actuator-moving Focus Types.
I2C Base Selection
The third area lets you set the base I2C address of the actuator, and depending on the actuator type will let you set / get register values.
Miscellaneous Selection
The fourth area has some miscellaneous items that be enabled/disabled.
- Disable Internal VCM; only enabled for sensors with this feature, it turns off the actuator as this can sometimes distort the image.
- Show AF Region; places an overlay on the displayed image indicating the area used to calculate the Sharpness score - the center 50% of the image.
- Reduce Region; reduces the AF Region from 50% to 25%