Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • In Manual mode, the slider bar allows quick movement of the actuator.
    • When the slider bar indicator is selected, left and right arrow buttons will move the actuator 1 value, and page up/down move the actuator by 20 values.
    • A position can be entered directly in the "Slider Pos" field, and then used with either "Return" or selecting "Trigger".
  • Sharpness score; displays the calculated sharpness score of the image - the higher the number, the more in-focus the image.
    • Displayed during Manual and other actuator-moving Focus Types.

I2C Base Selection

The third area lets you set the base I2C address of the actuator, and depending on the actuator type will let you set / get register values.

Miscellaneous Selection

The fourth area has some miscellaneous items that be enabled/disabled.

  • Disable Internal VCM; only enabled for sensors with this feature, it turns off the actuator as this can sometimes distort the image.
  • Show AF Region; places an overlay on the displayed image indicating the area used to calculate the Sharpness score - the center 50% of the image.
  • Reduce Region; reduces the AF Region from 50% to 25%